Any protocol using a standard serial port
will be available for serial devices which are Windows compatible, such as
multiport boards or serial to Ethernet products.
TOPKAPI can be used as an OPC server for each of the protocols listed hereafter,
except those for which "OPC" in mentioned in the SUPPORT column.
For protocols with time-stamped data, TOPKAPI provides built-in modem management
and historical data storage in any SQL compliant DBMS (Oracle, SQL Server, MySQL,
PostgreSQL, etc.).
TOPKAPI can be used as Gateway between several systems using distinct protocols.
Information below is applicable for the supply of the current TOPKAPI version. A
version update may be required when adding a new protocol driver to an old
TOPKAPI version, for technical or support reasons :
please contact us.
In Spanish, if this language is not available, the English
driver is installed, but it is also possible to install manually the French
version of the driver.
|
PROTOCOLS |
SUPPORT
|
Version
|
Language
|
OBSERVATIONS
|
|
ACT'L |
|
|
|
See EWON |
|
ADCON |
OPC Server |
32 |
Engl/Fr |
OPC Server provided by ADCON |
|
ALLEN BRADLEY |
All protocols |
OPC Server |
32 |
Engl/Fr |
Contact Allen Bradley or OPC server providers. |
|
DF1, DH485, DH, DH+, console plug |
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
Please contact Applicom
KF2 adapter required for DH+ |
|
Modbus, Modbus TCP |
TOPKAPI direct driver |
32 |
Engl/Fr |
Many providers of PLC communication cards (Allen Bradley, Prosoft) or gateways. |
|
AMPHITEC |
Standard serial port |
|
Fr |
|
|
AQUACOM |
Standard serial port |
32 |
Fr/Eng |
See ITT FLYGT |
|
ARITECH - MPI 232 |
Standard serial port |
16 |
Fr |
CD 150 Units |
|
ASI
(AS-i) |
Specialized card(3) |
32 |
Fr/Eng |
OPC Server requested, to be provided with the board |
|
Gateway |
32 |
Engl/Fr |
Gateway AS-I to Modbus, Modbus Plus, Profibus DP, Interbus,
DeviceNet, CANopen, CANrho (Bosch), CC-Link, LON, Modbus, TCP |
|
BACNET |
TOPKAPI direct driver |
32 |
Engl/Fr |
Ethernet port, serial connection via router. |
|
BAELZ |
Serial port or Modem |
32 |
Engl/Fr |
Jbus |
|
BATIBUS |
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
|
|
BERIS (DATAM) |
Standard serial port |
32 |
Fr |
|
|
CD 150 ARITECH |
|
|
|
See
ARITECH |
|
DDE |
Soft |
32 |
Engl/Fr |
All servers (1) |
|
DEF (NOVA, ALTARES, ANTARES) |
Standard serial port or Ethernet TCP/IP port |
32 |
Engl/Fr |
Fire Detection System Units (FDSU) & Fire Safety Controller
Units (FSCU). Preset objects FD & SAD, import, AUTOCAD links:
Please contact us for more details. |
|
DNP 3.0 |
OPC |
32 |
Engl/Fr |
OPC server developed by third party companies.
Please contact us |
|
ETHWAY, FIPWAY, MAPWAY |
Specialized card(3) |
32 |
Engl/Sp/Fr |
Windows 98/NT/2000/XP Pro
Librairie YCCFPWPCV1 (Fipway) or YCCETHPCV1 (Ethway) required |
|
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
Ethway, Fipway |
|
Specialized
card(3) |
16 |
Engl/Sp/Fr |
Only with Win 95/98, not WinNT: possible connection with the
SCHNEIDER basic drivers, delivered with the Fipway/Ethway card, using the
TOPKAPI 16 bits driver working in the compatibility mode. |
|
EWON |
Ethernet TCP/IP or standard serial port |
32 |
Engl/Fr |
|
|
GE - FANUC and CEGELEC SNP-X |
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
|
|
GE - FANUC Series 90-30 and 90-70 SRTP |
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
|
|
IDEC IZUMI |
Standard serial port |
32 |
Engl |
|
|
IEC 870-5-101 |
Standard serial port |
32 |
Engl/Fr |
|
|
Standard serial port + Modem |
32 |
Engl/Fr |
Modem link is not supported by all devices which are IEC 870-5-101 compliant.
Please contact us to confirm compliance of
the selected device with TOPKAPI. |
|
IEC 870-5-102
IEC 870-5-103 |
Serial, modem, radio |
32 |
Engl/Fr |
OPC server developed by third party companies:
please contact us. |
|
IEC 870-5-104 |
TCP-IP |
32 |
Engl/Fr |
GPRS compliant. |
|
INT2500 (Agbar) |
Modbus / Standard serial port |
32 |
Engl/Sp/Fr |
|
|
ITT FLYGT - MACTEC (Aquacom) |
Standard serial port |
32
|
Engl/Fr |
Self configuration by Softlink wizard using the .ATF files |
|
JBUS |
|
|
|
See MODBUS |
|
JOHNSON CONTROL: see OPTOMUX
and IM9100 |
|
32 |
|
|
|
LAC DDE server |
Soft |
32
|
|
|
|
LANDIS and STAEFA (RH 500, NITEL) |
Standard serial port |
32
|
|
|
|
LON.LONWORKS |
OPC |
32 |
Engl/Fr |
GESYTEC's EASYLON OPC Server successfully tested.
Others: please contact us |
|
MIRI (OVAL)
AD2000 (See also
time stamped
protocols) |
Standard port + Modem |
32 |
Engl/Fr |
Contacts :
Oval /
Miri |
|
OPC |
32 |
Engl/Fr |
|
MITSUBISHI FX |
OPC |
32 |
Engl/Fr |
OPC Server Melsec FX |
|
MODBUS JBUS Master |
Standard serial port |
32 |
Engl/Sp/Fr |
|
|
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
|
|
MODBUS/JBUS Slave |
Standard serial port |
32 |
Engl/Fr |
Can also be used for routing and / or communication
gateway |
|
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
|
|
MODBUS TCP-IP Master |
TCP-IP |
32 |
Engl/Sp/Fr |
|
|
MODBUS TCP-IP Slave |
TCP-IP |
32 |
Engl/Fr |
Can also be used for routing and / or communication gateway |
|
MODBUS PLUS |
Specialized cards(3) |
32 |
Fr/Sp |
|
|
MPI 232 |
|
|
|
See ARITECH |
|
NUGELEC |
Standard serial port |
16 |
Fr |
|
|
OMRON |
SYSMACWAY / Standard serial port |
32 |
Fr |
|
|
OPC Omron server |
32 |
Engl/Fr |
Please, consult OMRON |
|
OPC |
Depending on the server supplier |
32 |
Engl/Fr |
Please, consult us
if needed |
|
OPTOMUX |
Standard serial port |
32
|
Fr |
|
|
OTIC FISHER DATALINK |
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
|
|
PROFIBUS / SINEC L2 |
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
|
| OPC |
32 |
Engl/Fr |
OPC Server SCOUT.
Please contact SIEMENS for protocols handled and hardware
required. |
|
ROCKWELL |
|
|
|
See ALLEN BRADLEY |
|
SAC |
Standard serial port |
|
|
|
|
SAE-IT |
|
|
|
See IEC 870 |
|
SATCHWELL |
DDE MICRONET Server |
32 |
Fr |
Please, consult SATCHWELL
Local or remote via modem, no time stamped data |
|
SAUTER : See time stamped protocols |
Standard serial port |
32 |
Fr |
Serial (local)/modem (remote) link to Router/Routel
unit for fieldbus NOVANET |
|
SBUS - SAIA |
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
|
|
SCHNEIDER TELEMECANIQUE
ETHWAY, FIPWAY, MAPWAY |
Specialized card(3) |
32 |
Engl/Sp/Fr |
Windows 98/NT/2000/XP Pro
Librairie YCCFPWPCV1 (Fipway)
or YCCETHPCV1 (Ethway) required |
APPLICOM
card(4) |
32 |
Engl/Sp/Fr |
Ethway, Fipway |
Specialized card(3) |
16 |
Engl/Sp/Fr |
Only with Win 95/98, except WinNT: possible connection with
the SCHNEIDER basic drivers, delivered with the Fipway/Ethway card, using the
TOPKAPI 16 bits driver working in the compatibility mode. |
| OPC |
32 |
Engl/Fr |
Server OFS of Schneider Electric. To consult Schneider
according to your network and your equipment |
|
SCHNEIDER TCP/IP (See
Modbus-Jbus Master in TCP-IP too) |
Specialized card(3) |
32 |
Engl/Sp/Fr |
IPC UNI-TE library required |
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
|
|
SCHNEIDER ISAWAY |
Specialized card(3) |
32 |
Engl/Sp/Fr |
UNI-TE/ISAWAY PCUNI-TE library needed |
|
SCHNEIDER
UNITELWAY Slave |
|
Standard serial port |
32 |
Engl/Sp/Fr |
The driver can be used in slave mode
only. |
|
SCHNEIDER
UNITELWAY Master and Slave |
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
|
|
SCHNEIDER UNITY-PRO |
|
32 |
Engl/Fr |
According to the protocol in use (see
above), most frequently OFS, Schneider's OPC server |
|
SCHNEIDER ELECTRIC W@DE |
Standard serial port |
32 |
|
See Schneider
W@de Time stamped protocols |
|
|
| 3964R |
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
|
Standard serial port by the APPLICOM server SPWIN |
32 |
Engl/Fr |
(2) |
| AS511(S5) |
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
|
| Building Technologies CERBERUS |
Standard serial port or
Ethernet TCP/IP port |
32 |
Engl/Sp/Fr |
Via Modbus gateway provided by Siemens-Cerberus.
Fire Detection System Units (FDSU) & Fire Safety Controller
Units (FSCU). Preset objects FD & SAD, import, AUTOCAD links: please contact us
for more details. |
| Building Technologies LANDIS and STAEFA (RH500,
NIDES, NITEL) |
Standard serial port |
32 |
Fr |
NRK16, NRK9, NRV (A, B, C, D), NRD.
Details |
| INDUSTRIAL ETHERNET |
OPC Server SCOUT |
32 |
Engl/Fr |
OPC Server SCOUT
Please contact SIEMENS |
| OPC server Applicom(4)/Woodhead |
32 |
Engl/Fr |
OPC server Applicom/Woodhead
Applicom card not required (use of standard network adapter)
Please contact APPLICOM |
| SINEC H1 |
APPLICOM card(3) |
32 |
Engl/Sp/Fr |
|
| SINEC L1 |
DDE Server
(1) or APPLICOM
card(4) |
32 |
Engl/Fr |
|
| PROFIBUS / SINEC L2 |
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
|
| OPC |
32 |
Engl/Fr |
OPC Server SCOUT
Please contact SIEMENS
for protocols handled and hardware required. |
|
SNMP Manager |
Ethernet /
TCP-IP |
32 |
Engl/Fr |
Used for data acquisition |
|
SNMP Agent |
Ethernet /
TCP-IP |
32 |
Engl/Fr |
Used to make data available to SNMP manager.
Can be used as protocol gateway. |
|
SNP -X (GE - Fanuc and CEGELEC) |
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
|
|
SRTP (GE - Fanuc Serie 90-30 and 90-70) |
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
|
|
STRATEL |
Standard serial port + Modem |
32 |
Fr |
Please contact
us for hardware required. |
|
SUCOMA (KLÖCKNER-MOELLER) |
Standard serial port |
16 |
|
|
|
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
|
|
SULZER (SICOS) |
Standard serial port |
32 |
|
via Frontal:
please contact us. |
|
SYSMACWAY (OMRON) |
Standard serial port |
32 |
Fr |
|
|
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
|
| OPC server |
32 |
Engl/Fr |
|
|
TEXAS INSTRUMENTS TI-DIR (TI505) |
APPLICOM card(4) |
32 |
Engl/Sp/Fr |
|
|
UNITELWAY Master or Slave |
|
|
|
See SCHNEIDER
above |
N.B. : All the protocols without intermediary front end with a modem management
need a modem management library
|
PROTOCOLS |
SUPPORT
|
Version
|
Language
|
OBSERVATIONS
|
|
ABB Aquamaster |
SMS via GSM Modem |
32 |
Engl/Fr |
(5) |
|
ACT'L |
|
|
|
See EWON |
|
ADCON |
OPC Server |
32 |
Engl/Fr |
OPC Server provided by ADCON |
|
AQUACOM |
Standard port + Modem |
32 |
Engl/Fr |
See ITT FLYGT |
|
BACNET |
TOPKAPI direct driver |
32 |
Engl/Fr |
Ethernet port, serial connection via router. |
|
BAELZ |
Serial port or Modem |
32 |
Engl/Fr |
Jbus + specific time stamping |
|
BOBITECNIC |
Standard port + Modem |
32 |
Fr/Sp |
|
|
BOSCH D6600 |
Serial port |
32 |
Fr |
Front End Equipment D6600 |
|
CESA |
Frontal |
16 |
Fr |
Frontal PE1200 - Please contact us |
|
CR2M SAB600 / SAB6000 |
Standard port + Modem |
32 |
Fr |
|
|
CR2M ALNAEE |
Standard port + Modem |
32 |
Fr |
|
|
DATALOGGER IT |
File Protocol |
32 |
Fr |
Please contact us |
|
DATAM FLUTEC
TM 16000 XC
(F4 Front End) |
Standard serial port + F4 Front End |
32 |
Fr |
|
|
DATBUS2
(DATAM - FLUTEC / ARCANTE / APILOG) |
Standard port + Modem |
32 |
Fr |
|
|
DNP 3.0 |
OPC |
32 |
Engl/Fr |
OPC server developed by third party companies.
Please contact us |
|
ETIC |
Standard port + Modem |
32 |
Fr |
|
|
EWON |
TCP/IP or Standard port modem |
32 |
Engl/Fr |
|
|
GERRIS - SAPPEL |
|
|
|
See WAGAMET Ortomat |
|
EXEMYS |
Standard port + Modem |
32 |
Engl/Fr |
|
|
HYDREKA |
Eurolog |
Standard port + Modem |
|
|
|
|
Multilog / Octopus LS |
SMS via GSM Modem |
32 |
Engl/Fr |
(5) |
|
Octopus |
Standard port + Modem |
32 |
|
|
|
IDS ARCOS 750,
IDS 650/850 |
|
|
|
See IEC 870-5-101
and IEC 870-5-104 |
|
IEC 870-5-101 |
Standard serial port |
32 |
Engl/Fr |
|
|
Standard serial port + Modem |
32 |
Engl/Fr |
Modem link is not supported by all devices which are IEC 870-5-101 compliant.
Please contact us to confirm compliance of
the selected device with TOPKAPI. |
|
IEC 870-5-102
IEC 870-5-103 |
Serial, modem, radio |
32 |
Engl/Fr |
OPC server developed by third party companies:
please contact us. |
|
IEC 870-5-104 |
TCP-IP |
32 |
Engl/Fr |
GPRS compliant. |
|
IJINUS |
SMS via GSM Modem |
32 |
Fr |
(5) |
|
INT2500 AGBAR |
Standard port + modem |
32 |
Engl/Sp/Fr |
Modbus serial or modem, time stamped at the
source (Areal format) |
|
ISCO 2150 (TELEDYNE) |
Standard port + modem |
32 |
Fr |
|
|
ITT FLYGT - MACTEC (Aquacom) |
Standard port + modem |
32 |
Engl/Fr |
Self configuration by Softlink wizard using the .ATF files |
|
ITT FLYGT - SRX 104 Station (Aquacom) |
Standard serial port |
|
|
|
|
JEL |
Standard serial port |
|
|
|
|
JOHNSON CONTROL (IM9100) |
Standard port + Modem |
32 |
Fr |
|
|
KOSKAS Geoloc |
SMS via GSM Modem |
32 |
Engl/Fr |
(5) |
|
LANDIS AND STAEFA (RH500, NIDES, NITEL) |
Standard port + Modem |
32 |
Fr |
NRK16, NRK9, NRV (A, B, C, D), NRD.
Details |
|
MIRI (OVAL)
AD2000 (See
also real time protocols) |
Standard port + Modem |
32 |
Engl/Fr |
Contacts :
Oval /
Miri |
|
MODBUS JBUS Master |
Standard serial port |
32 |
Fr |
Time stamping at the source: SEPAM 2000 standard or
AREAL multiple formats. |
| Standard port + Modem |
32 |
Fr |
|
MODBUS TCP-IP Master |
TCP/IP |
32 |
Engl/Sp/Fr |
Time stamping at the source: SEPAM 2000 standard or
AREAL multiple formats. |
|
NAPAC |
Standard port + Modem |
32 |
Fr |
NAPBUS protocol |
| Standard port + Modem or TCP-IP Network |
32 |
Fr |
XFLOW type units: Flowtel, Phoenix, Rio, etc. |
|
PACSNET |
PACS Radio modem |
|
Fr |
|
|
PALMER Permanet |
SMS via GSM Modem |
32 |
Engl/Fr |
(5) |
|
PERAX |
Standard port + Modem or Arlequin Front End |
32 |
Fr/Sp |
P200, P200x, P400xi, P16XT |
|
PERAX SMS (P16XT) |
SMS via GSM Modem |
32 |
Engl/Fr |
(5) |
|
PRIMAYER |
Phocus |
SMS via GSM Modem |
32 |
Engl/Fr |
(5) |
|
Primelog |
Standard serial port + Modem |
32 |
Engl/Sp/Fr |
|
|
Xilog |
SMS via GSM Modem |
32 |
Engl/Fr |
(5) |
|
RADCOM - Multilog |
Standard port + Modem (PSTN) |
32 |
Fr/Sp |
|
| SMS via GSM Modem |
32 |
Engl/Fr |
(5) |
|
SAE-IT |
|
|
|
See IEC 870 |
|
SATCHWELL |
DDE MICRONET
Server |
32 |
Fr |
See real time protocols.
Remote acquisition via modem is available, but there is no time stamping of data
in the RTUs. |
|
SAUTER |
Standard port + Modem |
32 |
Fr |
Serial (local)/modem (remote) link to Router/Routel unit for
fieldbus NOVANET |
|
SCHNEIDER ELECTRIC |
W@DE |
Standard port + Modem |
32 |
Engl/Fr |
W@DE W320, W330, ... |
|
NAPBUS, XFLOW |
|
|
|
See NAPAC |
|
SDG (Lyonnaise des Eaux) |
TCP/IP Network card |
32 |
Engl/Fr |
|
|
SEBA Hydrometrie |
Standard port + Modem |
32 |
Sp/Fr |
MDS5 devices |
|
SECURITE COMMUNICATION (PE1200) |
Frontal |
16 |
Fr |
|
|
SERIEE |
PC EROS20 Frontal |
32 |
Fr |
|
|
SEVME (Sevbus) |
Standard port + Modem |
32 |
Engl/Fr |
|
|
SEWERIN Sepem |
SMS via GSM Modem |
32 |
Engl/Fr |
Leak prelocator.(5) |
|
SIEMENS LANDIS AND STAEFA (RH500, NIDES, NITEL) |
Standard port + Modem |
32 |
Fr |
NRK16, NRK9, NRV (A, B, C, D), NRD.
Details |
|
SOFREL LACBUS
(S500, LS10, LS42) |
Standard port + Modem |
32 |
Sp/Fr |
Support of event-driven communication
|
| TCP-IP / GPRS |
32 |
Sp/Fr |
Support of event-driven communication |
FR1000 Front End |
32 |
Fr |
|
|
SOFREL SOFBUS
(S10, S15, S40, S500, LS10, LS42) |
Standard port + Modem |
32 |
Sp/Fr |
Support of event-driven communication
|
| TCP-IP / GPRS |
32 |
Sp/Fr |
Support of event-driven communication |
CS100 / FR1000 Front
End |
32 |
Engl/Fr |
|
|
SOFREL SMS (CELLBOX, LS10, LS42) |
SMS via GSM Modem |
32 |
Fr |
(5)
|
|
SOFBUS (SOFREL)
S10, S15, S500, S510, S530, S550, LS |
Standard port + Modem |
32 |
Engl/Fr |
|
|
CS100 Front End |
32 |
Engl/Fr |
|
|
TBOX (Semaphore
- Technotrade) |
Standard port + Modem |
32 |
Engl/Sp/Fr |
|
|
TECHNOLOG |
CELLO |
SMS via
GSM Modem |
32 |
Engl/Fr |
(5) |
|
Newlog |
Standard
port + Modem |
32 |
Fr |
|
|
TRS II (WIT, AQUAVEIL) |
Standard port + Modem |
32 |
Engl/Sp/Fr |
|
|
MONET/Aquaveil II Frontal |
32 |
Engl/Sp/Fr |
|
|
WAGAMET Ortomat |
SMS via GSM Modem |
32 |
Engl/Fr |
(5) |
Many DDE servers are also available, and AREAL develops
protocols according to your requirements.